Systems & Solutions

Print
Bookmark
Share on
Facebook Twitter Linkedin
Contact us

GlobalRoof Thermo-Acoustic with sealing

CIN 339 T2-339 T3


Placed parallel on to intermediate non-structural trays
(can also be considered perpendicular to roof structure)
 
Width at load bearing supports for Trays HACIERCO C : 100mm minimum
 
GlobalRoof Thermo-Acoustic with sealing CIN 339 T2
1. Tray HACIERCO C500.90 perforated "P" 0,75mm thick (under condition of structural verification)
2. Purlin Cleat (see guide)
3. Mineral wool Sorock 90mm thick (Rockwool) (Asphalt Coated Glass)
4. Profile TRAPEZA 11.100.8 B 1,00mm thick
5. Stikson aluminium (Soprema)
6. MULTIBEAM Purlin (see guide)
7. Mineral wool Torock 120mm thick (Rockwool)
8. Tray  HACIERCO 40 SR 0,75mm thick (under condition of structural verification)
9. Mineral wool Rockacier 120mm thick (Rockwool)
10. Multilayer bitumen Sealing

Advantage: Esthethic

No visible ficing for the insulation on behind facade facing

GlobalRoof Thermo-Acoustic with sealing CIN 339 T3
1. Tray HACIERCO C400.90 perfoated "P" 0,75mm thick (under condition of structural verification)
2. Purlin Cleat (see guide)
3. Panolene cladding 50mm (Isover) (Asphalt Coated Glass)
4. Profile 3mm thick
5.  MULTIBEAM Purlin (see guide)
6. Feutral 80mm thick (Isover)
7. Tray HACIERCO 40 SR 1,25mm thick
8. Mineral wool Rockacier 120mm thick (Rockwool)
9. Multilayer bitumen Sealing

Advantages: Aesthetic

No visible ficing for the insulation on behind facade facing

Insulation