GlobalRoof Thermal DPN 30-25|DPP 30-25


Steel roofing 

GlobalRoof Thermal DPN 30
1. Steel cold roofing (Trapéza)
2. Insulation (λ = 0,040 W/m.K maxi) 120mm thick (unfolded between Purlins)
3. Purlin Cleat or spacer (see guide)
4. Purlin (see guide)
5. Insulation (λ = 0,040 W/m.K maxi) 60mm thick (gripped by spacers)
6. Profile Steel roofing: (Fréquence, Océane, Trapéza)
Up = 0,30 W/m².K estimation*
* Value estimated with spacing of purlins of  2,00 m 
It is requested to add a complementary insulation to fill the air gap between the panels

GlobalRoof Thermal DPN 25
1. Steel cold roofing (Trapéza)
2. Insulation (λ = 0,040 W/m.K maxi)160mm thick (unfolded between Purlins)
3. Purlin Cleat or spacer (see guide)
4. Purlin (see guide)
5. Insulation (λ = 0,040 W/m.K maxi)60mm thick (gripped by spacers)
6. Steel cold roofing: (Fréquence, Océane, Trapéza)
Up = 0,25 W/m².K estimation*
* Value estimated with spacing of purlins of  2,00 m 
It is requested to add a complementary insulation to fill the air gap between the panels  


GlobalRoof Thermal DPP 30
1. Non-structural Tray HACIERCO C 400.90 thick (thickness according to span)
2. Airtight vapour barrier
3. Purlin Cleat or spacer (see guide)
4. Insulation (λ = 0,040 W/m.K maximum) 90mm thick (at the bottom of te tray)
5. Purlin (see guide)
6. Insulation (λ = 0,040 W/m.K maximum) 60mm thick (unfolded between Purlins)
7. Insulation (λ = 0,040 W/m.K maximum) 60mm (gripped by spacers)
6. Steel cold roofing: (Fréquence, Océane, Trapéza)
Up = 0,30 W/m².K estimation*
 * valeur estimé avec entraxe panne = 2,00 m
Width at load bearing supports for Trays HACIERCO C: 100mm minimum

GlobalRoof Thermal DPP 25
1. Non-structural Tray HACIERCO C 400.90 thick (thickness according to span)
2. Airtight vapour barrier
3. Purlin Cleat or spacer (see guide)
4. Insulation (λ = 0,040 W/m.K maximum) 90mm thick (at the bottom of the tray), see guide.
6. Insulation(λ = 0,040 W/m.K maxi) 100mm thick (unfolded between Purlins)
7. Insulation (λ = 0,040 W/m.K maxi) 60mm thick (gripped by spacers)
6. Steel cold roofing: (Fréquence, Océane, Trapéza)
Up = 0,25 W/m².K estimation*
 * valeur estimé avec entraxe panne = 2,00 m
Width at load bearing supports for Trays HACIERCO C: 100mm minimum