Systems & Solutions

Print
Bookmark
Share on
Facebook Twitter Linkedin
Contact us

GlobalRoof Thermal KOMET®



GlobalRoof Thermal Komet® installation with a over-roof: ST 500
1. Non-wearer Tray HACIERCO C 400.90 with ou without perforations (thickness according to span)
2. Multibeam Purlin under Purlin Cleat or spacer
3. Insulation 90mm thick (at the bottom of the tray)
4. Airtight vapour barrier
5. Insulation: 150mm thick (between purlins)
6. Insulation: 120mm thick (unfolded between purlins)
7. Insulation: 60mm thick (placed above purlins and gripped by spacers)
8. Steel Profile: KOMET®
9. ZED profiles
10.Sidings: St 500
Up = 0,15 W/m².K*
* Value estimated with spacing of purlins of  2,00 m and λ-value Glass wool 0,040 W/m.K maximum 
 Width at load bearing supports for Trays HACIERCO C: 100mm minimum
It is requested to add a complementary insulation to fill the air gap between the panels


GlobalRoof Thermal Komet® installation with a photovoltaic over-roof
1. Non-structural Tray HACIERCO C 400.90 with or without perforations (thickness according to span)
2. Multibeam Purlin under Purlin Cleat or spacer (see guide)
3. Insulation: 90mm thick (at the bottom of the tray)
4. Airtight vapour barrier
5. Insulation: 150mm thick (between purlins)
6. Insulation: 120mm thick (unfolded between purlins)
7. Insulation: 60mm thick (placed above purlins and gripped by spacers)
8. Steel Profile: KOMET®
9. Photovoltaic Panel
Up = 0,15 W/m².K*
* Value estimated with spacing of purlins of  2,00 m and λ-value Glass wool 0,040 W/m.K maximum 
 Width at load bearing supports for Trays HACIERCO C: 100mm minimum
It is requested to add a complementary insulation to fill the air gap between the panels