GlobalRoof Thermo-Acoustic CIN 323 TP|CIN 338 T


Parallel to main tray  - Non-structural trays
(can also be considered perpendicular way)
GlobalRoof Thermo-Acoustic CIN 323 TP
1. Tray HACIERCO C 500-90 perforation "P" 0,75mm thick (under condition of structural verification)
2. Purlin Cleat or spacer (see guide)
3. Mineral wool Sorock 70mm (Rockwool)(Asphalt Coated Glass)
4. Vapeur barrier Rocksourdine (Rockwool)
5. Purlin (see guide)
6. Mineral wool Torock 200mm thick (Rockwool)
7. Profile: Hacierco 3.333.39 T 1,25mm thick (under condition of structural verification)
 
The installation should be carried out according to good practice: NF DTU 40.35 -  in accordance with the local professionals rules
 
Width at load bearing supports for Trays HACIERCO C: 100mm minimum
 

It is requested to add a complementary insulation to fill the air gap between the panels


GlobalRoof Thermo-Acoustic CIN 338 T
1. Tray HACIERCO C 500-90 perforations "P"0,75mm thick (under condition of structural verification)
2. Purlin Cleat or spacer (see guide)
3. Panolène cladding (Isover) (Asphalt Coated Glass)
4. Profile: Hacierba 1,00mm thick
5. Feutral 100mm thick
6. Purlin to obtain 220mm between Tray and profile (1 and 7)(see guide)
7. Profile: Fréquence, Océane, Trapéza 0,75mm thick (under condition of structural verification)
 
The installation should be carried out according to good practice: NF DTU 40.35 -  in accordance with the local professionals rules
 
It is requested to add a complementary insulation to fill the air gap between the panels
 

Insulation


Absorption