Systems & Solutions

Print
Bookmark
Share on
Facebook Twitter Linkedin
Contact us

GlobalRoof Thermo-Acoustic CN 125 RT


 Perpendicular to main trays - non-structural trays

(can also be considered parallel to roof structure)

Advantages: Aesthetic
No visible fixings for the insulation on behind facade facing
It is requested to add a complementary insulation to fill the air gap between the panels
GlobalRoof Thermo-Acoustic CN 125 RT
1. Tray HACIERCO C400.90 perfo "P" 0,75mm thick (under condition of structural verification)
2. Purlin Cleat or spacer (see guide)
3. Panolène Glass wool insulation panel 50mm thick (Isover)
4. Purlin (see guide)
5. Feutral Aluminium 50mm thick (between main purlins) (Isover)
6. Feutral 50mm thick (gripped on purlins) (Isover)
7. Profile: Fréquence, Océane, Trapéza 0,75mm thick (under condition of structural verification)

 

The installation should be carried out according to good practice: NF DTU 40.35 -  in accordance with the local professionals rules

 
Width at load bearing supports for Trays HACIERCO C : 100mm minimum
 

GlobalRoof Thermo-Acoustic CN 125 RT 1P
1. Tray HACIERCO C400.90 perfo "P" 0,75mm thick (under condition of structural verification)
2. Purlin Cleator or spacer (see guide)
3. Panolène Glass wool insulation panel 50mm thick (Isover)
4.Purlin (see guide)
5. Feutral Aluminium 80mm thick (between main purlins) (Isover)
6. Feutral 60mm thick (gripped on purlins) (Isover)
7. Profile: Fréquence, Océane, Trapéza  0,75 mm (under condition of structural verification)
 
Placing NF DTU 40.35 - Installation in accordance with the local professionals rules
 
Width at load bearing supports for Trays HACIERCO C : 100mm minimum
 

GlobalRoof Thermo-Acoustic CN 125 RT P15
1. Non structural Tray HACIERCO C450.70 perforation "P" 0,75mm  thick (under condition of structural verification)
2. Panolène Glass wool insulation panel 70mm thick (Isover)
3. Vapeur barrier sealing (see guide)
5. Glass wool 150mm thick (unfolded between purlins)
6. Glass wool 120mm thick (crosed et unfolded between purlins)
7. Glass wool 60mm thick (unfolded between purlins)
8. Profile: Fréquence, Océane, Trapéza  0,75mm thick (under condition of structural verification)

 
The installation should be carried out according to good practice: NF DTU 40.35 -  in accordance with the local professionals rules
 
Width at load bearing supports for Trays HACIERCO C : 100mm minimum
 

Insulation


Absorption