Systems & Solutions

Print
Bookmark
Share on
Facebook Twitter Linkedin
Contact us

GlobalRoof Thermo-Acoustic IN 220 RT - 225 TR


IN 220 RT : Perpendicular to main tray - non-structural trays
 (can also be considered perpendicular to roof structure)
IN 225 TR : Parallel to main tray  - structural trays
Width at load bearing supports for Trays HACIERCO C: 100mm minimum
GlobalRoof Thermo-Acoustic ribbed roof IN 220 RT
1. Tray HACIERCO C400.90 0,75mm thick (under condition of structural verification)
2. Vapour barrier (ou pontage des lèvres et raccord des plateaux)
3. Purlin Cleat or spacer (see guide)
4. Cladding Panolene 70mm thick (Isover)
5. Purlin
6. Feutral cladding 80mm thick
7. Profile: Fréquence, Océane, Trapéza 0,63mm thick (under condition of structural verification)

It is requested to add a complementary insulation to fill the air gap between the panels

Advantages: Aesthetic
No visible fixings for the insulation on behind façade facing

GlobalRoof Thermo-Acoustic ribbed roof IN 225 TR

1. Tray HACIERCO C500.90 0,75mm thick (under condition of structural verification)
2. Purlin Cleat or spacer (see guide)
3. Mineral wool Sorock 70mm thick (Rockwool)
4. Rocksourdine (Rockwool)
5. Purlin (see guide)
6. Mineral wool Torck 200mm thick (Rockwool)
7. Profile: Trapéza 1,25mm thick


Advantages: Aesthetic
No visible fixings for the insulation on behind façade facing

Insulation